Pages

Showing posts with label RTTE. Show all posts
Showing posts with label RTTE. Show all posts

Monday, December 12, 2016

5 Questions on the new Radio Equipment Directive 2014/53/EU (RED)


Coming into force on June 13, 2016, and half way through the transition period, the Radio Equipment Directive (RED) 2014/53/EU replaces the Radio and Telecommunications Terminal Equipment Directive (R&TTED)  1995/5/EC and over the past few months I've received numerous questions regarding the transition to the new directive. This isn't an all inclusive list or a full transition guide, far from it, I recommend that you consult a RED Notified Body with your specific needs for that. 


Here are the 5 most common questions I receive.



"Do I need to apply the new directive immediately?"
No, the RED came into force on June 13th 2016, however, article 48 gives a transitional provision accepting the old directive for radio equipment covered by the RED until June 12, 2017. That is to say you must apply the RED to covered radio equipment on or after June 13th 2017.


"Should I start testing to the new directive now?"
I get this a lot, and it's a very common misconception. One does not simply "test" to a Directive, you declare compliance to the Directive. 

The directive contains the essential requirements of compliance, among other laws, governing the "making available on the market" of Radio Equipment. Testing is one method for demonstrating compliance with the essential requirements, but the actual test methods are found outside the directive, referred to as "Harmonised Standards" under the directive. 

While in order to use a "Harmonised Standard" for presumption of conformity, it must be published with reference to the RED in the Official Journal, the new directive doesn't change harmonized standards, but it may impose new "essential" requirements that could impact your testing.


"Can I start "declaring" compliance to the new directive?"
Probably not. Article 17 of the RED describes the conformity assessment procedures. There are three annexes describing the available methods. (Annex II Internal Product Control) (Annex III EU-type examination) and (Annex IV Full Quality Assurance).

By far Internal Production Control is the most commonly used conformity assessment method and it's the only method that does not require 3rd party involvement of a Notified Body, but in order to apply Annex II, you must test in full to published harmonized standards. The problem is that the list of harmonized standards published under the new RED is small compared to the R&TTE. Chances are at the moment the particular harmonized standard previously applied has not been adapted and referenced to the RED, but the list is growing. See https://celectronics.com/certification/europe/ for links to the published harmonized standards.

Another issue here is that there is a change, however so slightly, in the requirements from the R&TTE article 3.2. This small change adds a new requirement to be assessed, and that is that the Radio Equipment "supports the efficient use of radio spectrum". New technical standards will need to incorporate this requirement.


"If I can't test in full to published harmonized standards, is there a method to comply with the RED now?"
Yes, there are a couple as mentioned above, Annex III EU-Type examination and Annex IV Full Quality Assurance. Of the two, EU type examination would generally be the most practical for most organisations that don't have the ability or wish to submit to a full quality assurance assessment or the continued surveillance required of that system.

EU-Type examination is a method by which the manufacturer submits an application to a "single" Notified Body of their choice. The Notified Body will review the technical design and verify the equipment complies with the essential requirements of the RED and if so issue an EU-Type examination certificate. This would be combined with the manufacturer's own assessment and the Declaration of Conformity (which will include the Notified Body number). The manufacturer would then affix the CE mark to the equipment (without including the Notified Body number)

 “If I test to the current harmonized standards for the R&TTE and write my declaration to the R&TTE now, what do I need to do June 13th, 2017?”
On or after June 13th 2017, all equipment that falls within the scope of the RED must be assessed to be in compliance with the RED prior to placing on the market in the European Union. This does not apply to equipment already on the market (sold or in the EU), only new shipments being placed on the market. The declaration of conformity must follow the new Model Structure and the manufacturer shall also establish the required technical documentation described in Article 21 of the RED. Also note that in addition to the technical test report the manufacturer is required to provide a risk assessment within their technical documentation.











Friday, May 23, 2014

New Radio Equipment Directive Published

European Union flag

European Union flag (Photo credit: YanniKouts)

The new Radio Equipment Directive (RED) 2014/53/EU, replacing the R&TTE directive, has been published in the Official Journal of the European Union. The directive enters into force 20 days after publication and shall be transposed and become applicable 24 months after the date of entry into force.

Products have one extra year before they must comply with the new requirements. Products that comply with the current EU R&TTE directive 1999/5/EC can be placed on the market up to 36 months after the date of entry into force.

Publication in the OJEU was on 22nd May 2014.

Ref:

RTTE-CA presentation by the European Commission Unit F5

Directive 2014/53/EU http://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=OJ:JOL_2014_153_R_0002&from=EN

Tuesday, December 4, 2012

Radio module integration and R&TTE compliance, EMC evaluation

radio module

radio module (Photo credit: ckhamken)

Building on a previous post focusing on radio module integration and the Radio and telecommunications terminal equipment (R&TTE) directive compliance, this article will focus on compliance of the combined apparatus with section 3.1(b) of the R&TTE directive, namely the essential requirements of Electromagnetic Compatibility or EMC.

As a basic primer, the R&TTE directive’s essential requirements are detailed within the directive under article 3, to paraphrase;

3.1 Essential requirements applicable to all apparatus;

       a. Safety requirements of the Low Voltage Directive, with lower limits removed

       b. Electromagnetic compatibility as per EMC directive

3.2 Effective use of radio spectrum

3.3 Construction, protection and accessibility requirements (with a number of specified items)

As posited in a previous post “Radio module integration and R&TTE compliance”, compliant radio modules installed in accordance with a manufacturer’s installation instruction require no further evaluation to article 3.2 of the R&TTE directive. However, an assessment, in most cases, will be necessary for article 3.1(a) and 3.1(b). The combined product will essentially form a new apparatus.

Given that the combined product should be assessed as a new apparatus, a couple questions may arise. What EU directive and standards apply? How do you make an assessment for EMC on the combined product?

When adding a radio to an apparatus, the new combined apparatus now falls within the scope of the R&TTE directive. ETSI EN 301 489-1 annex C gives guidance regarding this combined equipment EMC assessment, and it is based on the ETSI TR 102 070-1 technical report. In accordance with the guidance, for a combined apparatus where all products can operate independently of each other, an evaluation may be made by review of existing assessment of the individual apparatus, and if it is concluded that the combined configuration has been assessed and is representative of the combined apparatus, and, is used in according to its manufacturer’s instructions, it is not necessary to re-assess the apparatus. If there is insufficient information to make an evaluation, or the results of the evaluation are unclear, then an additional assessment shall be performed. Most of the time an assessment for EMC of the combined apparatus will not have been performed, or there is insufficient data to support a declaration of conformity.

Although under the scope of the R&TTE directive, the selection of applicable standards for EMC will be based on the primary function of the newly combined apparatus. The manufacturer shall declare the primary function and identify applicable standards from the EMC directive and/or R&TTE directive. The assessment should be supplemented with test levels and extended frequency ranges to cover both radio and non-radio aspects of the newly combined apparatus (i.e. a worst case representation of applicable levels and limits). See this flow chart from Compatible Electronics for a simplification of the assessment process based on the ETSI guidance.

The declaration of conformity will need to declare compliance with the R&TTE directive, and the party responsible for the completed combined apparatus is the party responsible for ensuring that the final configuration, when used properly, and in accordance with the provided instructions, fulfills ALL essential requirements of the R&TTE directive.

 

REF:

ETSI TR 102 070-1

ETSI EN 301 489-1 annex C

R&TTE CA TGN 01 Rev 5

GUIDELINES ON THE APPLICATION OF DIRECTIVE 2006/95/EC (par. 34)

Wednesday, October 24, 2012

R&TTE Directive List of Harmonized standards updated

A new list of “Harmonised” standards has been published in the Official Journal of the European Union with reference to the Radio and Telecommunications Terminal Equipment  Directive 1999/5/EC .

Below is a table of the most recent updates, or go directly to the full Publication of titles and references of harmonised standards under the directive.

 

ESO (1)

Reference and title of the harmonised standard
(and reference document)

Reference of superseded standard

Date of cessation of presumption of conformity of superseded standard
Note 1

Article of Directive 1999/5/EC

Cenelec

EN 50360:2001/A1:2012 (new)

Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300 MHz - 3 GHz)

Note 3

13/02/2015

Article 3(1)(a)

Cenelec

EN 60730-1:2011 (new)

Automatic electrical controls for household and similar use -- Part 1: General requirements
IEC 60730-1:2010 (Modified)

   

Article 3(1)(a) (and Article 2 2006/95/EC) + Article 3(1)(b)

Cenelec

EN 61000-3-12:2011 (new)

Electromagnetic compatibility (EMC) -- Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <= 75 A per phase
IEC 61000-3-12:2011

EN 61000-3-12:2005
Note 2.1

16/06/2014

Article 3(1)(b)

ETSI

EN 300 220-2 V2.4.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 2: Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

EN 300 220-2 V2.3.1
Note 2.1

28/02/2014

Article 3(2)

ETSI

EN 300 328 V1.8.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

EN 300 328 V1.7.1
Note 2.1

31/12/2014

Article 3(2)

ETSI

EN 301 489-17 V2.2.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems

EN 301 489-17 V2.1.1
Note 2.1

31/05/2014

Article 3(1)(b)

ETSI

EN 301 489-34 V1.3.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 34: Specific conditions for External Power Supply (EPS) for mobile phones

EN 301 489-34 V1.1.1
Note 2.1

28/02/2014

Article 3(1)(b)

ETSI

EN 301 559-2 V1.1.2 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM);Short Range Devices (SRD); Low Power Active Medical Implants (LP-AMI) operating in the frequency range 2 483,5 MHz to 2 500 MHz;Part 2: Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

   

Article 3(2)

ETSI

EN 301 843-1 V1.3.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for marine radio equipment and services; Part 1: Common technical requirements

EN 301 843-1 V1.2.1
Note 2.1

31/05/2014

Article 3(1)(b)

ETSI

EN 301 893 V1.7.1 (new)

Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

EN 301 893 V1.6.1
Note 2.1

31/12/2014

Article 3(2)

ETSI

EN 302 288-2 V1.6.1 (new)

Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices; Road Transport and Traffic Telematics (RTTT); Short range radar equipment operating in the 24 GHz range; Part 2: Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

EN 302 288-2 V1.3.2
Note 2.1

31/12/2013

Article 3(2)

ETSI

EN 302 774 V1.2.1 (new)

Broadband Wireless Access Systems (BWA) in the 3 400 MHz to 3 800 MHz frequency band;Base Stations;Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

EN 302 774 V1.1.1
Note 2.1

31/12/2013

Article 3(2)

NOTE: Date Format is the European Date Format DD/MM/YYYY (List is an excerpt for the list provided at http://ec.europa.eu/enterprise/policies/european-standards/harmonised-standards/ and only represents new items)

For links to this and lists for other directives, please visit Compatible Electronics’ European Conformity Assessment page.

Friday, October 19, 2012

Update to Radio Equipment Rules proposed by European Commission

Outside the Berlaymont building of the Europea...
Outside the Berlaymont building of the European Commission (Photo credit: Wikipedia)
The European Commission proposed on Wednesday to update the Radio Equipment Directive. The proposal has three main goals;
  1. To Strengthen the level of Compliance with the Directive
  2. To Clarify the Directive
  3. To Simplify the Directive
Market surveillance will be a big part of the primary objective to strengthen the level of compliance. The new requirements will clearly spell out the responsibilities and obligations for every market player be it the manufacturer or importer. Simplification will come in the form of reduced administrative overhead such as suppression of notification requirements of certain products. The proposal also introduces some new requirements such as control of Software, and Interoperability with accessories, and networks.

The new R&TTE directive is also to be aligned with the New Legislative Framework (NLF). The NLF negotiations were conducted at the Member States level, and without consideration for specific Directives. As a result many of the New Approach Directives have become misaligned with the NLF. In late 2011 a package of 9 other recast draft directives, “aligned” with the NLF have been submitted to the EU Council and Parliament.

· Low Voltage Directive 
· EMC Directive
· ATEX Directive
· Lifts Directive
· Simple Pressure Vessels Directive
· Measuring Instruments Directive
· Non-automatic Weighing Instruments Directive
· Civil Explosives Directive
· Pyrotechnic Articles Directive
 
Ref:
Draft RE directive
http://europa.eu/rapid/press-release_IP-12-1109_en.htm
http://ec.europa.eu/enterprise/sectors/rtte/documents/legislation/review/index_en.htm
http://ec.europa.eu/enterprise/policies/single-market-goods/regulatory-policies-common-rules-for-products/new-legislative-framework/









Friday, July 20, 2012

Class 1 Status of 2.4 GHz Wireless LAN in the EU

Class 2 Label sample EU R&TTE. Provided by;
Compatible Electronics, Inc..

Confirmed during a Radio and Telecommunications Terminal Equipment Compliance Association (R&TTE CA) meeting held in Vienna, May 2012, the French deviation has expired for the 2.4 GHz band making it a Class 1 band.

Till this point, the 2.4 GHz band has been considered Class 2 in the EU, that is, when importing your product, it must carry the number of a notified body and a special alert symbol in addition to the CE Mark, and you must notify member nations having restrictions, of your intention to place the product on the EU market. Additionally, the product literature would carry a warning of the restriction to “Indoor use only”.

While the notification requirements for the 2.4 GHz use have been eliminated for some time, the last item preventing the 2.4 GHz WLAN from being classified officially as a Class 1 R&TTE device went away on July 1st. The French deviation in the band restricting use of 2.4 GHz WLAN devices to “Indoor use only” has expired.

From July 1, 2012, 2.4 GHz WLAN devices no longer require the alert symbol or Notified Body number, so long as harmonized standards are applied in full to the conformance assessment.

For an explanation of what the class descriptor indicates, see this excerpt from the ETSI.org web site;

“Commission Decision 2000/299/EC defines how equipment is classified according to its use of radio spectrum. It defines two equipment classes as follows:

  • Class 1, which can be placed on the market and taken into service throughout the Community

  • Class 2, to which some Member States apply restrictions and which is required to carry an 'alert symbol'.”

Ref;

R&TTECA

ETSI.org

http://www.art-telecom.fr/

http://www.erodocdb.dk/Docs/doc98/official/pdf/REC7003E.PDF

Thursday, June 14, 2012

Multimedia Equipment, emission requirements standard EN 55032 held up due to errors.

Back of audio mixer at bull and gate london

Back of audio mixer at bull and gate London (Photo credit: Wikipedia)

The CEN-CENELEC Management Centre (CCMC) was informed that a considerable number of errors were discovered during the publishing phase of the new EMC standard for multimedia equipment, CISPR 32:2012. The procedure has been endorsed by CENELEC as EN 55032:2012 (dor = 3/5/12). It has been noted that the document submitted for vote was the correct text however.

While the IEC is investigating possible options for correcting the matter, CCMC is informing of the errors and working with the IEC toward a speedy resolution to enable CENELEC members to implement corrections at the national level. The CCMC has also posted a note to the CENELEC website / database informing of this error.

The CCMC will not yet offer EN 55032:2012 to the European Commission for citing in the Official Journal. The intended listing was for the EMC and Radio and Telecommunication Terminal Equipment ( R&TTE)  Directives.

Furthermore the Technical Committee will request that the Date of Withdrawal (DOW) be extended from dor+36 months to dor+60 months.

EN 55032:2012 has a broad scope and applies to multimedia equipment (MME) having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. Equipment within the scope of CISPR 13 (EN 55013) or CISPR 22 (EN 55022) is within the scope of EN 55032. Multimedia equipment intended primarily for professional use is also within the scope of EN 55032.

The term “dor” refers to the date of ratification, and is the date when the technical board notes the approval of a European Norm (EN), at which time the standard may be said to be adopted.

Ref:

CENELC Project : EN 55032:2012

CENELEC Guide 19

Wednesday, April 11, 2012

New R&TTE and EMC Standards List Published in OJ

New Harmonized standards lists have been published in the Official Journal of the European Union for the Radio and Telecommunication Terminal Equipment(R&TTE) Directive and the EMC Directive.

R&TTE Directive Standards List

EMC Directive Standards List

Wednesday, February 29, 2012

2011 market surveillance report EU –are tablet PCs a target for 2012?

English: CE logo

Image via Wikipedia

Bundesnetzagentur (Federal Network Agency) of Germany, for Electricity, Gas, Telecommunications, Post and Railway has the responsibility to carry out the market surveillance under the EMC and R&TTE Directives.

The agency published a summary of the 2011 market surveillance campaign on its web site. The campaign’s primary focus in 2011 was with the EMC directive and in particular, LED lighting equipment. The report also combines results from the 2010 and 2011 campaigns to give a summary overall and to achieve a low error probability due to the larger sample size.

For some background on emissions concerning LED product, see July 2011 post “Radio interference from LED lighting”.

The surveillance looked at administrative conformity, such as marking, documentation and declarations, as well as the technical aspects of the directive namely compliance with the emissions and immunity requirements. A total of 168 products were sampled in 2011.

On the administrative side, the surveillance found that 76.8% of the samples were compliant with the CE marking requirements, while only 39.9% were compliant with the Declaration of Conformity (DoC) requirements.

For the technical assessment, 61.5% of product complied with the radio emissions requirement, and 91.3% were found immune to specific interference phenomenon, out of 46 products tested overall.

In total, only 17.3% of LED lighting equipment was found to be fully compliant.

For the “reactive market surveillance”, the overall rate of non-compliance for electromagnetic compatibility (EMC) was 38.9%. For radio and telephone terminal equipment (R&TTE) a majority, 65.5%, was found non-compliant according to the report, but most concerning was that 75.6% of the R&TTE products checked were non-compliant with the safety and health measurement requirements.

The 2011 surveillance resulted in 90 EMC sales bans, 177 R&TTE sales bans, 353 “memoranda of understanding” between the two directives, and total revenues of €1,046,000

The report details some objectives for 2012 indicating supporting the revision of the EMC and R&TTE directives and transposition into national law, including harmonizing product assessment for market surveillance, and increasing cooperation with European market surveillance and customs authorities as well as adapting the national database for market surveillance results, to the European ICSMS database.

Two product group targets were mentioned for 2012, one a coordinated German/Dutch campaign targeting tablet PCs focused on the R&TTE directive, and another targeting “Ready-made connecting devices”, or laptop power supplies.

 

ref;

Market surveillance statistics 2011

Tuesday, October 25, 2011

Updated list of standards published in the Official Journal of the European Union, under the R&TTE directive, on 9/21/11.

Find a copy on Compatible Electronics', European Conformity Assessment page, or at http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:C:2011:277:0001:0035:EN:PDF


Friday, October 21, 2011

Q&A; applicability of EMC directive to SIM (subscriber identity module)

Question:

Application of the EMC Directive to SIM.

“Does the EMC Directive apply to smart cards, SIM cards and other contact cards? If so, what do you think are the applicable standards?”

Answer:

My understanding is that the common SIM requires an external power source and data interface to function, so assuming the SIM card performs no independent intrinsic function, and thus is not considered an "apparatus", but rather a "component" or "Sub-assembly" and must be paired with a device designed to operate with it, the EMC directive is not independently directly applicable to the SIM.

However, the SIM will be subjected to the same environment the intended host is subjected to, so it should be capable of compliance under such conditions, and with whatever directive(s) the host, or hosts, are governed by, and should not compromise the compliance of any given host. However, testing in one configuration considered "Typical" does not automatically guarantee compliance in all use cases.

Testing to a given set of harmonized standards is one of the tools used to assess compliance with the essential requirements of a given directive, but is not a requirement in and of itself, nor does it guarantee compliance with the essential requirements.

The broader the use case, the broader the assessment needs to be. Consider mobile phones, medical devices, information technology equipment, etc...

----------------------

Note the “Answer” to the question presented is only opinion, but based on extensive knowledge of the applicable EMC requirements. The responsibility for compliance with any requirement rests with the given product manufacturer.

Friday, May 27, 2011

Do you mind turning off your RF device please?

Tin Foil Hat
Image by James Provost via Flickr
According to a Parliamentary Assembly of the Council of Europe (PACE) report issued May 6, 2011, “waiting for high level scientific and clinical proof that electromagnetic fields emanating from high frequency sources such as radar, telecommunications and mobile phones may lead to very high health and economic costs”.
PACE will be meeting in Kyiv on May 27th, and hold a debate, and intends to adopt a resolution on the issues raised in the report.
The report invokes heath concerns, in particular using examples of asbestos, lead, and tobacco, as mistakes made in the past when dealing with unknown health risks. The report also likens the potential consequences on the environment by electromagnetic fields with licensing of medication, chemicals, pesticides, heavy metals and genetically modified organisms.
The report recommends that an “as low as reasonably achievable” approach be adopted when setting standards or threshold values for emissions of electromagnetic fields of all types and frequencies. The report urges that particular attention should be given to protecting children, and “electrosensitive” persons suffering from a syndrome of intolerance to EM fields with a call to protect them from the unknown effects of electromagnetic waves by the creation of “Wave-free” areas not covered by wireless networks.
Mobile phones, DECT phones, WiFi, WLAN and WIMAX come under focus in the reports, with the call for microwave long-term exposure thresholds of not to exceed 0.6 v/m and in the medium term reduced to 0.2 v/m. The report also makes recommendations to; undertake risk-assessments prior to licensing new types of devices, calls for additional labeling and indications of health risks, produce warnings and recommendations to use a wired alternative due to the “unknown” dangers of electromagnetic fields..
The report proposes the ban of all mobile phones and wireless networking devices from schools and classrooms.

By:

Tuesday, November 16, 2010

EMC List of Harmonized standards published

Test Chamber

Image by CmdrFire via Flickr

An updated list of harmonized standards under 2004/108/EC, the EMC directive, has been published in the Official Journal of The European Union.

Find a copy of this list, along with updated lists for the R&TTE Directive 1999/5/EC, Low Voltage Directive 2006/95/EC, Medical Device Directive 93/42/EEC, and ERC Recommendation 70-03 relating to the use of Short Range Devices, at http://www.celectronics.com/europe.htm

Enhanced by Zemanta

Thursday, July 8, 2010

Radio module integration and R&TTE compliance

Wireless UFO?Image by jepoirrier via Flickr

Compliance with the EU Radio and Telephone Terminal Equipment directive (R&TTE) is compulsory for radio devices. The responsibility for compliance is placed clearly on the manufacturer of the device. When integrating a radio module into a completed product, the integrator then becomes the “manufacturer” of the radio device. The underlying basis for this is that the integration of the two products can affect final compliance with the directive.

Technical reports from ETSI, ETSI TR102 070 parts 1 and part 2, give guidance related to the integration of radio modules into final product, already assessed for EMC, and the application of harmonized standards. These documents, together with the directive, form the basis of guidance notes developed by R&TTE notified bodies for the assessment of product to the directive.

In all cases, assessments must be made for compliance with R&TTE directive article 3.1(a), and 3.1(b). These articles cover Safety and EMC, respectively.

According to a quote in the guidance document;

“Assessed radio modules installed in equipment in conformance with the manufacturer's installation instructions require no further evaluation under Article 3.2 of the R&TTE Directive and do not require further involvement of an R&TTE Directive Notified Body for the final product. In all other cases, or if the manufacturer of the final product is in doubt then the equipment integrating the radio module must be assessed against Article 3.2 of the R&TTE Directive.”

ETSI Technical Report ETSI TR102 070-2, describes several applications of the above with different product configurations.

When the integration of a particular module does require assessment by a notified body, the technical documentation for the radio module will need to be reviewed by the NB, if not available, the NB may request this information from the radio module manufacturer. The NB may be unable to issue an opinion without this information. The integrator should ensure that the module manufacturer is willing to provide this information to the NB; however, the final Technical Construction File is not required to include the radio module manufacturer’s proprietary information. Furthermore, the final product integrator is cautioned to ensure that they know the build status of the integrated module.

The R&TTE guidance document also covers technical documentation, notification to national authorities, and marking requirements.

The full guidance document can be downloaded here http://www.rtteca.com/TGN01Rev4.pdf


Be sure to visit http://www.celectronics.com/europe.htm for more information related to EU regulatory compliance.


UPDATE: part II available covering EMC considerations - 

Radio module integration and R&TTE compliance, EMC evaluation

Wednesday, March 10, 2010

List of ETSI 301 489 EMC standards applicable under article III 1.(b) of 1999/5/EC ( R&TTE Directive ).

This is a flat list of the ETSI 301 489 series test standards. For more information on any of these, visit http://pda.etsi.org/pda/queryform.asp for a direct search on the ETSI site. This list and other R&TTE related material is available on the Compatible Electronics European Conformity Assessment page.

ETSI EN 301 489-1 Common Technical requirements
ETSI EN 301 489-2 Specific conditions for radio paging equipment
ETSI EN 301 489-3 Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz
ETSI EN 301 489-4 Specific conditions for fixed radio links, Broadband Data Transmission System Base stations, ancillary equipment and services
ETSI EN 301 489-5 Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech)
ETSI EN 301 489-6 Specific conditions for Digital Enhanced Cordless Telecommunications (DECT) equipment
ETSI EN 301 489-7 Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)
ETSI EN 301 489-8 Specific conditions for GSM base stations
ETSI EN 301 489-9 Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and in-ear monitoring devices
ETSI EN 301 489-10 Specific conditions for First (CT1 and CT1+) and Second Generation Cordless Telephone (CT2) equipment
ETSI EN 301 489-11 Specific conditions for terrestrial sound broadcasting service transmitters
ETSI EN 301 489-12 Specific conditions for Very Small Aperture Terminal, Satellite Interactive Earth Stations operated in the frequency ranges between 4 GHz and 30 GHz in the Fixed Satellite Service (FSS)
ETSI EN 301 489-13 Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and non-speech)
ETSI EN 301 489-14 Specific conditions for analogue and digital terrestrial TV broadcasting service transmitters
ETSI EN 301 489-15 Specific conditions for commercially available amateur radio equipment
ETSI EN 301 489-16 Specific conditions for analogue cellular radio communications equipment, mobile and portable
ETSI EN 301 489-17 Specific conditions for Broadband Data Transmission Systems
ETSI EN 301 489-18 Specific conditions for Terrestrial Trunked Radio (TETRA) equipment
ETSI EN 301 489-19 Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications
ETSI EN 301 489-20 Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS)
ETSI EN 301 489-22 Specific conditions for ground based VHF aeronautical mobile and fixed radio equipment
ETSI EN 301 489-23 Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) Base Station (BS) radio, repeater and ancillary equipment
ETSI EN 301 489-24 Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment
ETSI EN 301 489-25 Specific conditions for CDMA 1x spread spectrum Mobile Stations and ancillary equipment
ETSI EN 301 489-26 Specific conditions for CDMA 1x spread spectrum Base Stations, repeaters and ancillary equipment
ETSI EN 301 489-27 Specific conditions for Ultra Low Power Active Medical Implants (ULP-AMI) and related peripheral devices (ULP-AMI-P)
ETSI EN 301 489-28 Specific conditions for wireless digital video links
ETSI EN 301 489-29 Specific conditions for Medical Data Service Devices (MEDS) operating in the 401 MHz to 402 MHz and 405 MHz to 406 MHz bands
ETSI EN 301 489-31 Specific conditions for equipment in the 9 kHz to 315 kHz band for Ultra Low Power Active Medical Implants (ULP-AMI) and related peripheral devices (ULP-AMI-P)
ETSI EN 301 489-32 Specific conditions for Ground and Wall Probing Radar applications
ETSI EN 301 489-33 Specific conditions for Ultra Wide Band (UWB) communications devices

Friday, January 8, 2010

R&TTE Directive 1999/5/EC HS Corrigendum

Cleveland (European Parliament constituency)

Image via Wikipedia

A new and amended list of Harmonized Standards for the Radio and Telecommunications Terminal Equipment Directive, replacing the one issued 12/2/09, has been publish in the official journal of the European Union.

Please visit http://celectronics.com/pdf/OJlistRTTE121509.pdf for a copy of the OJ list.

Reblog this post [with Zemanta]

Wednesday, December 2, 2009

R&TTE updated list of harmonized standards

Official Journal of the European Union

Image by ex_libris_gul via Flickr

A new list of harmonized standards for the Radio and Telephone Terminal Equipment directive (R&TTE) has been published in the official journal.

Get a copy of the list here.

Visit our European Conformity Assessment page for this and other lists of harmonized standards updated regularly.

This information can be found at the EUR-Lex web site providing access to European Union law.

Reblog this post [with Zemanta]

Monday, July 13, 2009

ETSI Standards Published

ETSI EN 302 264-1 V1.1.1 (2009-06) Short Range Devices; Road Transport and Traffic Telematics (RTTT); Short Range Radar equipment operating in the 77 GHz to 81 GHz band; Part 1: Technical requirements and methods of measurement

ETSI EN 302 264-2 V1.1.1 (2009-06) Part 2: Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

Technical Reports, not harmonized standards,  but of possible interest:
ETSI TR 102 763 V1.1.1 (2009-06) Short Range Devices (SRD); Technical characteristics of Detect-And-Avoid (DAA) mitigation techniques for SRD equipment using Ultra Wide Band (UWB) technology

ETSI TR 102 651 V1.1.1 (2009-06) Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Guide to the implementation of Dynamic Frequency Selection (DFS)

ERO invites comment

ERO invites comment on ECC Report 137: Introducing greater flexibility in the current regulatory structure with a view to taking forward convergence and harmonization in the ECC
http://www.ero.dk/C1A7F777-8817-4121-90B1-C8A46B753575?frames=0

Closing date 8/24/08, Point of contact gulyaev@ero.dk

Friday, July 10, 2009

Safety requirements, European standards for personal music players

European Commission Decision of 23 June 2009 on the safety requirements to be met by European standards for personal music players pursuant to Directive 2001/95/EC of the European Parliament and of the Council

http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2009:161:0038:0039:EN:PDF

Note: the mandate under R&TTED/LVD is not yet available and so AP7 from Cardiff meeting cannot yet be actioned.  Meanwhile, NBs are advised to note this Decision when formulating opinions covering personal music players.